Chapter 3 · From points to objects

Detection to verified outcome

One incident, one record

Operations / command centre

Incident lifecycle

5 open · synthetic
1Detected
2Correlated
3Triaged
4Dispatched
5On site
6Resolved
7Verified
Illustrative incident queue with SLA and ownership
IncidentStatusPriorityOwnerSLA
VerifiedP2Synthetic technician · T-1736 / 90 min
On siteP1Synthetic guard · G-089 / 30 min
TriagedP2Synthetic event lead · E-0628 / 480 min
DetectedP2Unassigned4 / 240 min
DispatchedP3Synthetic lift technician · L-1120 / 1440 min

Two occupied work zones are losing comfort; no life-safety system is affected. Owner: Tower B mechanical response.

Alarm-flood comparison · illustrative

Less noise. More consequence.

1,240point alarms
37object conditions
6incidents
Signature story · illustrative synthetic operations

AHU-TB-12-04 · the stuck valve

TB12 / F12 / AHU04
Flat point alarm queueNo shared asset, location or service context
TB12.SAT19.8 °CSupply-air temperature high
TB12.CWV100 %Cooling valve command saturated
TB12.ZT-03+2.7 °CZone-temperature deviation
02:00–04:00Typical human correlation to dispatch (illustrative)

Meanwhile, warmer return water increases plant load and the first comfort complaint arrives in a separate system.

  1. Condition detected

    Cooling output diverged from valve command across three consecutive observations.

  2. Object graph correlated

    TB12.SAT, TB12.CWV and TB12.ZT-03 bound to AHU-TB-12-04; zones 12-A and 12-B resolved.

  3. Incident INC-2026-1109-041 triaged

    P2 priority derived from two occupied zones and the affected cooling service.

  4. Technician T-17 dispatched

    Nearest qualified technician selected from the illustrative live roster; evidence and asset history attached.

  5. Occupant channel notified

    Affected space owners received the scope and 10:45 illustrative ETA before a complaint was logged.

  6. Fix confirmed on site

    Valve travel checked from 0–100%; feedback tracked command within ±3%.

  7. Outcome verified

    Supply-air temperature recovered to 14.2 °C and command fell to 62%; the 14-minute verification window passed.